FLIR KF6-RSU Mountable Thermal Imaging Cameras View larger

FLIR KF6-RSU Mountable Thermal Imaging Cameras

New product

F6 Unit, 640, NTSC, 30Hz, Right Side Up Mounted

money back 2.jpg

More details

10 Items

$5,852.00

More info

Features

  • KF6 Unit, 640, NTSC, 30Hz, Right Side Up Mounted
  • High-angle thermal view of rooftops
  • Securely fixed-mounted under or atop aerial platforms
  • New TIC vantage point
  • Single cable with a MIL-C connector
  • Aerial mounting flexibility
  • Best resolution shows you more
  • Convenient monitoring
  • CDMQ ruggedness
  • 640 × 480 IR resolution and a 69°

Specifications

General Specifications
Imaging and optical data
IR resolution 640 × 480 pixels
Thermal sensitivity/NETD < 100 mK at f/1.4
Field of view (FOV) 69° × 56°
Focus Fixed
F number 1.4
Image frequency 30 Hz
Detector data
Detector type Focal plane array, uncooled microbolometer
Spectral range 7.5–13.5 μm
Image presentation
Image mode TI Basic firefighting mode
Auto range Yes
Measurement
Object temperature range
  • High-gain range: –25 to +135°C (–13 to +275°F)
  • Low-gain range: 0 to +550°C (+32 to +1022°F)
Accuracy ±10°C (±18°F) or ±10% in high gain range
Measurement analysis
Spotmeter 1
Isotherm Yes
Configuration
Video standard NTSC
Mounting Top mounted
Temperature unit °F
Composite video
Video out Composite video output, NTSC compatible
Power system
Power input 10.5–32 V DC ( ISO 7637-2)
Start-up time < 25 seconds
Power consumption < 5 W average, when supplied with 28 V DC
Connector
Power and video connector 13-pin MIL-C-38999, D38999/24FB35PN
Mating connector: D38999/26FB35SN
Environmental data
Operating temperature range –32 to +65°C (–26 to +149°F)
Storage temperature range –40 to +70°C (–40 to +158°F)
Humidity (operating and storage) IEC 600 68-2-30, 24 hours, 95% relative humidity, 25–40°C (77–104°F), two cycles
EMC
  • EN 61000-6-2:2005 (immunity)
  • EN 61000-6-3:2011 (emission)
  • FCC 47 CFR Part 15 B (emission)
  • ISO7637-2 Road Vehicles – Electrical Disturbances from conduction and coupling – Part 2: Electrical transient conduction along supply lines only. (Immunity)
Encapsulation IP 67 (IEC 605 29)
Shock IEC 600 68-2-27, 25g peak half sine wave
Vibration IEC 600 68-2-6, 0.15 mm 10 Hz to 58 Hz and 2 g 58 to 500 Hz sinusoidal
Physical data
Weight 1.2 ± 0.1 kg (2.6 ± 0.2 lb.)
Size (L × W × H) 158 mm × 112 mm × 89 mm (6.2 in. × 4.4 in. × 3.5 in.)
Housing material Aluminum
Color White and black